Part of this kit — included in the price above.

Senville 3 Ton 18.6 SEER2 Central AC Unit Heat Pump - Top Discharge - R-32 - 230V

Senville 3 Ton 18.6 SEER2 Central AC Unit Heat Pump - Top Discharge - R-32 - 230V

Senville| SKU: SENTC-36TD-16 In Stock

$3,499.99$4,399.0020% off

Payment plans

From $291.66/mo with shop Pay View sample plans

$97.22/mo with Paytomorrow Learn More

SAVE NOW:
Free Delivery Jul 25-Aug 1 (Est.)
Line Set Length
Optional accessories

Add common accessories before checkout.

Add coverage
Add coverage

Choose optional coverage for your order.

Protection plan

Use your system worry-free for years to come

  • Comprehensive coverage for mechanical and electrical breakdowns, including power surges
  • Repairs covered 100% for the extended term — labor included, not just parts
  • Coverage for normal wear and tear that affects how the product works
  • Replacement or reimbursement if we can’t repair it
  • $0 deductibles, ever
  • Cancel anytime on a pro-rata basis
  • US-based support and quick claims filing
2-year protection · $149Add two years of optional service contract coverage. 5-year protection · $299Add five years of optional service contract coverage.

Coverage begins after the manufacturer warranty applies, and runs alongside it for items the factory doesn’t cover. Select a plan above the Add to Cart button to include it with your order.

Backed by Chill Mini Splits · (888) 231-8920Detailed terms and conditions

Product overview

Senville 3 Ton 18.6 SEER2 Central AC Unit Heat Pump - Top Discharge - R-32-230V

Designed for both summer cooling and winter heating, this system delivers reliable performance across a wide outdoor temperature range, including heating operation down to -4°F. It also uses modern R-32 refrigerant, offering efficient performance in a next-generation HVAC platform.

Built for efficiency, durability, and consistent comfort, the Senville 3 Ton Central AC Heat Pump is a smart choice for homeowners upgrading to a modern all-season heating and cooling system. Professional installation is required.

Key Features:

  • 3 ton / 36,000 BTU-class central heat pump system
  • High-efficiency performance with up to 18.6 SEER2
  • Provides both cooling and heating from one system
  • Top-discharge outdoor unit directs airflow upward
  • DC inverter compressor for quieter, more efficient operation
  • Strong cold-weather heating performance down to -4°F
  • Uses R-32 refrigerant
  • 208/230V single-phase power
  • Ideal for medium-sized homes and ducted central HVAC applications

Specifications:

Specification Value
Efficiency Ratings
SEER2 18.6 BTU/W
EER2 11.7 BTU/W
HSPF2 (Region 4) 9.0 BTU/W
COP (Heating) 3.20 W/W
Cooling Performance
Rated Cooling Capacity 34,000 BTU/h
Cooling Capacity Range 13,000 – 38,000 BTU/h
Cooling Input Power 2,906 W (range: 460–3,600 W)
Cooling Current Draw 13.2 A (range: 2.1–16 A)
Capacity @ 109°F Outdoor 32,000 BTU/h
Capacity @ 5°F Outdoor 34,000 BTU/h
Cooling Operating Range (Outdoor) 5°F – 131°F
Heating Performance
Rated Heating Capacity 36,000 BTU/h
Heating Capacity Range 11,000 – 39,000 BTU/h
Heating Input Power 3,300 W (range: 600–3,600 W)
Capacity @ 47°F Outdoor 36,000 BTU/h
Capacity @ 17°F Outdoor 17,500 BTU/h
Capacity @ 5°F Outdoor 27,000 BTU/h
Capacity @ –4°F Outdoor 25,000 BTU/h
Heating Operating Range (Outdoor) –4°F – 75°F
Electrical
Power Supply 208/230V, 60 Hz, 1-Phase
Indoor MCA / MOP 5 A / 15 A
Outdoor MCA / MOP 24 A / 30 A
Compressor RLA 9.45 A
Outdoor Fan Motor RLA / Output 2.3 A / 200 W
Indoor Fan Motor RLA / Output 3.6 A / 375 W
Communication Wiring AWG 25×3 Shielded
Refrigerant & Piping
Refrigerant Type R-32
Factory Refrigerant Charge 2.9 kg (102.3 oz)
Additional Charge Rate 0.52 oz/ft (48 g/m)
Liquid / Gas Line Size 3/8 in / 3/4 in
Max. Pipe Length 246 ft (75 m)
Max. Height Difference 98.4 ft (30 m)
Connection Method Flared
Throttle Type (Outdoor / Indoor) EXV / Piston
Compressor
Compressor Type Twin-Rotary DC Inverter
Compressor Model / Brand KTM240D57UMT / GMCC
Airflow & Sound
Indoor Airflow — High / Low 1,110 / 520 CFM
Indoor Noise Level — High / Low 50 / 38 dB(A)
Outdoor Airflow (Max) 2,800 CFM
Outdoor Noise Level 58 dB(A)
Dimensions & Weight
Indoor Unit (W × D × H) 21-1/32" × 21-1/32" × 49-7/32"
Indoor Net / Gross Weight 137 / 151 lbs
Outdoor Unit (W × D × H) 29-9/64" × 29-9/64" × 25"
Outdoor Net / Gross Weight 143 / 151 lbs

In-stock systems ship fast and free with curbside freight delivery, typically arriving in 4–10 days. Please inspect each box at delivery and note any damage on the receipt before signing — it keeps any freight claim quick and simple.

Ask AI

Ask AI about this product

Ask our AI product assistant about sizing, compatibility, electrical needs, accessories, shipping, warranty, and install planning.

At a glance

Tech specs

Power230 Volt
Mount typeDucted
InstallationProfessional installation required
BrandSenville

Sizing in doubt? Our HVAC experts confirm capacity for your rooms before you order — free. Ask us about utility rebates for high-efficiency heat pumps in your area.